Item |
Specifications |
Notes |
Rated speed (m/s) |
1.0 |
1.6 |
1.75 |
|
Rated capacity (kg) |
630 |
630 |
630 |
Only applicable to NZ11S |
825 |
825 |
825 |
Applicable to HY05S, NZ11S, NZ22S, NZ31S. |
1050 |
1050 |
1050 |
Applicable to HY05S, NZ11S, NZ22S, NZ31S. |
1200 |
1200 |
1200 |
Only applicable to NZ32S. |
1350 |
1350 |
1350 |
Only applicable to NZ32S. |
Number of stops (floors) |
2-18 |
2-18 |
2-18 |
Only applicable to NZ32S. |
2-22 |
2-22 |
2-22 |
Only applicable to HY05S. |
2-22 |
2-30 |
2-30 |
When applicable to NZ11S, NZ22S, and NZ31S. |
Travel TR (m) |
3.4-55 |
7.3-80 |
7.3-80 |
When applicable to NZ11S, NZ22S, and NZ31S. |
3.4-40 |
7.3-40 |
7.3-40 |
Applicable when NZ31S and CAP=1050kg and through the door. |
3.4-55 |
7.3-60 |
7.3-60 |
When applicable to HY05S and NZ32S. |
Clear entrance height HH (mm) |
2100 |
2100 |
2100 |
Standard. |
2200, 2300, 2400 |
2200, 2300, 2400 |
2200, 2300, 2400 |
Optional, applicable to NZ11S, NZ22S, NZ31S. |
2200, 2300 |
2200, 2300 |
2200, 2300 |
Optional, when NZ32S is applicable. |
Car internal height HL (mm) |
2300 |
2300 |
2300 |
Standard. |
2200, 2400, 2500 |
2200, 2400, 2500 |
2200, 2400, 2500 |
Optional, applicable to NZ11S, NZ22S, NZ31S. |
2400 |
2400 |
2400 |
Optional, when applicable to HY05S and NZ32S. |
Speed mode |
Standard |
Standard |
Standard |
Not applicable to HY05S. |
Variable speed (VSE) |
|
|
Not applicable to HY05S. |
Variable speed range |
1.0~1.6 |
1.0~1.6 |
|
Only when the speed mode is variable speed. Not applicable to HY05S. |
SETS feature |
Do not configure |
Optional |
Optional |
When the speed mode is variable speed. Not applicable to HY05S. |
Operating mode |
1C~2BC, 2C~2BC, 2C~AI-22, 3C~AI-22, 4C~AI-22 |
The operation mode is 2C~2BC when only NZ31S single door is opened. |
Roping |
2:1 |
|
Control mode |
VFGLC |
|
Door system |
LV0K-L2N-CO |
|
LV1K-L3N-2S |
Only applicable to NZ11S |
Door opening method |
Central Fraction (CO) |
|
Bi-fold (2S) |
Applicable only when NZ11S. |
Door opening direction |
Open the door on the left, open the door on the right |
Only applicable when the NZ10S door opening method is bi-folding. |
Door opening type |
Single door opening (1D1G) |
Standard. |
Through-through door (1D2G) |
Optional, only applicable to NZ31S. |
Through Door (2D2G) |
Non-standard, only applicable to NZ31S. |
Electrical power supply |
380V50Hz three-phase five-wire system |
|
Mains power |
220V50Hz single phase |
|
Lighting powe |
Side-on |
|
CWT safety gear |
Not configured; configured |
|
Min. floor height (mm) |
2800: with concrete corbels (by customer) |
HH=2100. |
2600: with steel corbels (by SMEC) |
HH=2100. |
Hall indication range |
B1, B2, B3, B4, B5, B, G, M, -1, -2, -3, -4, -5, 1, 2, 3, 4, 5, 6 , 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, -22, 23, 24, 25, 2627, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 47, 483A, 5A, 12A, 13A, 15A, 17A, 23A, 12B |
|